Invenco Group Ltd G7UPC Benutzerhandbuch

Seite von 67
G7OPT Integrator Manual, DWI-00175 S1 R15
The G7SDC will display a “RT event” screen; the G7UPC will display a slow (once a second) red keypad
LED indication:
Fig. 3.2:
SDC Removal Tamper (RT) event screen
3.2 Removal Tampers
Removal tampers are designed with integrators and their agents in mind; they maintain financial security
while allowing legitimate operations, such as installation or swap-out by service staff. While in the
removal-tamper state, the following operations are possible using TMSlite:
• clearing removal tampers
• installing packages
• retrieving logs
The following sections describe the steps for:
• connecting an Invenco product to external tamper sensors that will protect it within an integrated
system
• clearing the removal-tamper state and promoting the unit to normal operation.
The reverse steps, for removing a unit, need no explanation; they should be straightforward and largely
mechanical. In contrast with installing a device and clearing its removal-tampered state, cryptographic
authentication is unnecessary. The main security considerations when removing a unit are to avoid an
accidental DSR in the process and not to lose it afterwards.
Note:
It is strongly recommended to retrieve all logs before unit removal, for problem-solving and
root-cause analysis.
Chapter 3. Tampers
14