II. The Power Supply 
An AC power adapter is required to connect to a 
wall outlet. Only use the supplied DC 5V output and 
micro USB adapter with the 1050 control panel. 
Activating Rechargeable Backup Battery 
 
In addition to the adapter, an internal 
rechargeable battery in the Control Panel will 
serve as a backup in case of a power failure. 
 
The battery is a 3.7V 560 mAH  
Ni-mH rechargeable battery pack. 
 
During normal operation, the AC power 
adapter supplies power to the Control Panel 
and recharges the battery. 
 
To charge the battery and have the battery 
supply backup power in the event of a power 
loss, remove the rubber battery switch cover 
and slide the battery switch to “ON” with a  
 
When the battery is fully charged, it can 
provide back-up power for a period of at least 
12 hours: It takes approximately 48 hours to 
fully charge the battery.
  
III. Connecting the Telephone Line 
A telephone jack is located on the left side of the 
panel for the connection to your telephone line. 
Plug one end of the enclosed telephone cable into 
the jack on the wall and the other end of the cable 
into the socket on the VHS-1050 marked “Line.” 
IV. How to Install the Dialer 
The easiest way to get to know the system and get 
it up and running quickly is to place all the devices 
and accessories programmed on a tabletop before 
locating and mounting them. 
The Dialer can be mounted on the wall or wherever 
desired. Make sure that the Dialer is positioned at 
approximately chest height, so that the display may 
be easily seen and the keypad will be convenient to 
operate. 
 
Using the Wall Mounting Bracket as a 
template, mark the positions of the two (2) 
holes. 
 
Drill the holes, then install the screws and 
dowels provided. 
 
Place the VHS-1050 unit onto the Wall 
Mounting Bracket, with the front facing 
towards you.  
V. Getting Started 
Power supplied by an external 5V DC power 
adaptor: Two (2) beeps are emitted and the Power 
LED Green flashes ON indicating that it has entered 
Normal Mode.  
Continue to program the unit as instructed in next 
section. 
 
Programming the 1050 
 
All programming and pairing of devices with the 
1050 control panel sensors and VC100 valve 
controller may be done the Vital Home Systems PC 
software.  The software may be downloaded from 
Vital Home Systems Website at: 
You  must  register  your  1050  on  the  Vital  Home 
Systems Website to download the software. 
The Software is written only for Windows version 10 
through Vista.  Download and install the software to 
your  Windows  Desktop  prior  to  plugging  the  1050 
USB cable into the computer and the 1050 Control 
Panel. 
 
1050 Local Programming 
Quick Reference Chart 
 
1050 in Normal mode Commands 
Function 
Keypad operation 
Enter program mode 
SET + # + (pin code) + SET 
Recording 
SET hold 5 secs 
Play Custom Recording 
SET + 1 + SET 
Clearing alarms 
ACK Key 
Commands while in 1050 Program mode 
Function 
Keypad operation 
Set phone number 
SET  +  (1~10)  +  #  +  (phone 
number) + SET 
Clear phone number 
SET + (1~10) + SET 
Test phone number
 
TEST + (1~10) + SET 
Cold Water Valve id(1~64) close 
SET + 20 + # + (1~64) + SET 
Hot Water Valve id(1~64) close 
SET + 20 + # + (1~64) + * + SET 
Cold Water Valve id(1~64) open 
SET + 21 + # + (1~64) + SET 
Hot Water Valve id(1~64) open 
SET + 21 + # + (1~64) + * + SET 
Valve automation feature setting off
 
SET + 30 + SET 
Valve automation feature setting on
 
SET + 31 + SET 
Water sensor & Valve Range Test 
TEST + 80 + SET 
Pin code (passcode) change 
SET + 90 + # + (pin code) + SET