Vital Home Systems LLC 1050 Benutzerhandbuch

Seite von 14
P a g e
 | 
 
 
© 2015 Vital Home Systems 
Range Testing 
Step 1: With the Dialer in Programming Mode, 
press “Test” key followed by “8.” 
The Power LED Red will flash, indicating that it 
has entered Range-Test Mode. 
Step 2: Press Sensor Test buttonThe Power LED 
Red flashes ON for one (1) second then a long 
beep will sound, indicating that signal has been 
successfully received at this distance range.  
The Dialer LED will also flash ON, enabling the 
person testing the range from afar to see the 
condition in case the beep cannot be heard.  
NOTE: 
  Once a sensor has been successfully 
Learned-In, the Dialer LED will stay lit for 
another 60 seconds to allow you to Learn-In 
the next one. 
  Once in Range-Test Mode, if a key is not 
pressed for 30 minutes, the Dialer will 
sound five (5) quick-beeps then 
automatically exit Range-Test Mode and 
return to Program Mode. 
  You may exit Range-Test Mode to return to 
Programming Mode anytime by pressing 
“CLR” key. 
  To exit Programming Mode and return to 
Normal Mode, press “CLR” key. 
  To enter Range-Test Mode, return to  
Step 1. 
Change Password  
Step 1: With the Dialer in Programming Mode, 
enter the Old PIN number followed by the 
“CLR” key. A one-second beep will emit, 
indicating that you have entered Change –
Password Mode.  
Step 2: Press the New PIN number followed by the 
“SET” key. A one-second beep will be emitted 
indicating that the password change was 
successful. 
 
NOTE: 
 A key-press interval of five (5) seconds is 
allowed; if five seconds are exceeded before 
the next key-press or incorrect entry, it will 
automatically abort the process. A quick 
four-beep sound will be emitted to indicate 
return to Program Mode.  
 To enter Change-Password Mode, return to 
Step 1.  
 You may exit Change-Password Mode 
anytime by pressing “CLR” key. 
 To exit Programming Mode and return to 
Normal Mode, press “CLR” key. 
Exit Programming Mode 
Press “CLR” key to exit the Programming Mode and 
return to Normal Mode. 
Recording Custom Audio 
The 1050 Control Panel allows the user to create a 
10 second custom audio recording that will play as 
part of the message when a leak is detected.  Vital 
Home  Systems  recommends  recording  the  1050 
location such as an address, unit number or building 
number to provide unique ID for the system. To do 
the custom recording: 
Press and hold the SET button for 5 Seconds, when 
you  hear  the  beep  begin  speaking.    When  done 
release the SET button.  We suggest you speak about 
4 inches away from the mic on the panel face clearly 
and distinctly.  To play back the recording press SET 
+ 1.  To re-record. Repeat the process. 
Reset Dialer to Default Settings 
Step 1: Remove all power sources, including AC 
power adaptor and battery. (To remove the 
battery remove the 4 black feet and unscrew 
the 4 case screws.  Be careful not to over 
tighten the screws when putting back together 
so as not to strip the screw holes. Unplug the 
battery from the PC board). 
Step 2: With the panel apart keeping the “CLR” key 
pressed, plug in the AC power adaptor. A long 
one-second beep will emit indicating that the 
Panel has been successfully reset to Default 
Settings. 
Step 3: Plug the battery back in and close the case 
carefully not to over tighten the screws. 
NOTE: 
Under Factory Default Setting – 
 
PIN code is set as “0000” 
 
VHS-1050 is cleared of all telephone 
numbers. 
 
VHS-1050 is cleared of all sensor devices.