Vital Home Systems LLC VC100 Benutzerhandbuch

Seite von 17
P a g e
 | 10 
 
 
© 2015 Vital Home Systems 
alarm. Do not clear the alarm on the control panel until the VC100 batteries have been replaced.  
After 
replacing the low batteries with fresh batteries supplied by Vital Home Systems you MUST push and hold 
the red button on the bottom for 3 seconds and release to clear the alarm on the control panel. 
Self-Check Mode  
The VC100 will automatically rotate the water valve to CLOSED then OPEN every 180 days.  This ensures 
the VC100 is operating normally and helps keep hard water scale from building on the ball valve impeding 
proper operation. There is no alert for this unless there is a fault if the valve failed to close. 
 
Valve Failed to Close or Open 
The common cause of this is a loose wire connected to the round motor assembly.  This will trigger a 
very loud car alarm noise.  Check the wiring to the motor and depress the red button on the bottom. For 
3 seconds. 
 
 
Factory Reset 
NOTE: Factory Reset removes paired devices and control panels from the VC100 and the system 
MUST be go through pairing process again with the sensors and control panel to function normally 
and stop water leaks. 
Step 1. Make sure that both sources of power supply (AC adaptor and backup battery) are working 
normally.   
Step 2. Press and hold the Master Switch for more than 1 sec.  
Step 3. Unplug the AC adaptor from VCM (without removing battery). 
Step 4. Hold down the Master Switch for 2 more secs, then release the switch. VCM will perform 2 
short beeps followed by a long beep to indicate that all the data in EEPROM has been cleared.  
NOTE:  If the beeps are not performed, it means reset is not successful.  It is necessary to repeat 
Steps 1~4. 
Step 5. Plug the AC adaptor back to VCM. 
 
Opening the Valve if the Motor Stops Functioning 
Remove the four large Hex bolts on the bottom of the Valve Coupler Mount.  Once the VC100 base is 
removed, you will have access to the valve stem.  For ¾ inch, 1 inch 1-1/4 inch valves use a long 3/8 
socket with a socket wrench to turn the valve.  For 1-1/2 inch and 2 inch valves use a 7/16 long socket.  
You can tell valve position by the slot on the valve stem. If the slot in the valve stem is in line with the 
pipe, the valve is OPEN.  If the slot on the valve stem crosses the pipe the valve is CLOSED.