Vital Home Systems LLC VC100 Benutzerhandbuch

Seite von 17
P a g e
 | 
 
 
© 2015 Vital Home Systems 
VC100 Operation and Functions 
 
Pairing Options 
The VC100 is typically paired with a control panel such as the Vital Home Systems 1050 or Vital Home 
Systems 1060 4G.  PC Software downloaded from the Vital Home Systems website is used to pair the 
VC100 with Control Panels. See Vital Home Systems Website at 
 page. 
 
The VC100 also may be paired directly with the Vital Home Systems water sensors 4LWS.  Contact Vital 
Home Systems for direction on this pairing mode.  
NOTE: There is NO reporting of a water leak or system 
malfunction in this mode. Holding the Master switch in for more than 5 seconds may cause the VC100 
to enter learn mode and cause it to remove the wireless connection to the control panel. 
 
The only way to “Unpair” water sensors from the VC100 is to perform a factory reset on the VC100. 
Normal Operation 
IMPORTANT  NOTICE  TO  USER:    The  installation  of  any  water  detection  or  automatic  water  shut  off 
system does NOT guarantee water will be detected on all occasions or circumstances.  Due to the variety 
of environments the system can be installed, how it is maintained and types of installation, Vital Home 
Systems does NOT guarantee or warrant against water or property damage as a result or/with the use 
of this system. 
 
The normal state for the VC100 is with the valve in the OPEN position awaiting a command from the  
Vital Home System Control Panel it is paired with. 
 
When a leak is detected by a water sensor that has been paired with a control panel, the control panel 
will send a CLOSE VALVE command to the VC100 and the VC100 will shut the water valve.  
 
The VC100 will send the following commands to the control panel during normal operation or when a 
fault is detected: 
  If the valve closed successfully it will send a “Valve Closed Successful” report to the control 
panel 
  If the valve failed to close it will send a “Valve Failed to Close” report to the control panel 
  If the VC100 batteries are less than 4.4 V DC it will send a “Low Battery” report to the control 
panel 
  If the VC100 notices a fault it will send a “Fault Detected” report to the control panel. 
  The VC100 sends an “I’m here” report to the control panel every 12 hours.  If the control panel 
loses connectivity with the control panel, the control panel will send out a “Fault Detected” 
report for the VC100. 
Low Battery Condition 
Once a “Low Battery” report is received. Replace the batteries in the VC100 as soon as possible.  NOTE: 
If the “Low Battery” report is cleared on the control panel the user will not receive another low battery