Streaming Data Output Parameters:  . . . . . . . . . . . . . . . .  Day of the Month, Time in GMT & 24 hour format, Latitude & 
Longitude, Wind direction (in degrees), Wind Speed (1 min. average 
in mph), High Wind Speed (in mph in the last 5 min.), Temperature 
(°F), Rainfall (inches) in the last hour, Rainfall (inches) in the last 24 
hours, Daily Rainfall (inches since midnight), Humidity (in %, omitted 
if missing), Barometric pressure (mb/hPa, omitted if missing), Solar 
Radiation (in W/m2, omitted if missing).
W e a t h e r L i n k   f o r   A l a r m   O u t p u t   w i t h   C o n n e c t o r   B l o c k   ( #   6 5 4 4 )
The Connector Block is designed to allow you to turn heaters, fans, and other devices on or off using the data from 
your weather station. The utility software steps you through the choices. For each of four outputs, you can enter up 
to eight different weather parameters. Enter threshold values for each, select from nine different test conditions, and 
logically combine the entries together as you choose. Our connector block provides the interface between your 
Vantage Pro2 console or Weather Envoy and an electrical device. For high-power devices, you may also need to add 
electrical relays (not supplied by Davis Instruments).
H a r d w a r e   I n s t a l l a t i o n   a n d   R e q u i r e m e n t s
In addition to the requirements for WeatherLink, the Irrigation capability has the following additional hardware 
requirements.
• Computer running 98, 98SE, ME, 2000, XP, or Vista with Microsoft .NET 2.0 framework. Requires at least 
3 MB of RAM and 512 KB of hard disk space.
• Relays: You may need to obtain your own relays in order to switch equipment at voltages higher than 
28 volts or power levels above 10 Watts.
Caution:
The Alarm Output data logger is not suitable for any use in which the health or safety of any person or the value or pro-
tection of valuable property is dependent on the operation of the device.
F u n c t i o n a l   S p e c i f i c a t i o n s
Operating Temperature . . . . . . . . . . . . . . . . . . . . . . . . . .  -40° to +140° F (-40° to +60° C)
Output Contact Closures . . . . . . . . . . . . . . . . . . . . . . . . .  4 Alarm Contact Specifications, Terminal Block with stainless steel 
cage clamp screw terminals.
Each of the four output contacts is rated as follows:
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Photo-coupled MOS FET
Load Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  28VAC or 48VDC
Peak Voltage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ± 60 V, maximum
Load Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ± 1.8 A, continuous maximum at 77°F (25°C), derated to 0.7 A at 
185°F, (85°C)
Peak Load Current  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6 A for 100 msec., maximum
ON Resistance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  0.12 Ohms, maximum
OFF Leakage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1 uA, maximum
Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  550 mW, maximum
Output Contact Closure Functions (Set through the configuration software utility):
Station Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . .  Allows user to configure available test parameter list based on station 
model and accessories.
Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Allows user to enter test parameters in English or metric.
Available Test Parameters  . . . . . . . . . . . . . . . . . . . . . . .  Outside Temperature, Outside Humidity, Outside Dewpoint, Current 
Wind Speed, 10 min average Wind speed, Wind Direction, Wind Chill, 
Outside Heat Index, Barometer Value, Barometer Trend: (Rising 
Rapidly, Rising Slowly, Steady, Falling Slowly, Falling Rapidly), Daily 
Rain, Storm Total Rain, Monthly Rain, Yearly Rain, Rain Rate, Solar 
Radiation, UV Radiation, Inside Temperature, Inside Humidity, Inside 
Dewpoint, Inside Heat Index, Extra Temperature (1- 8: # based on Tx 
ID), Extra Humidity (1- 8: # based on Tx ID) Daily ET, Monthly ET, 
Yearly ET, Leaf Wetness (1-2), Soil Moisture (1-4), Leaf Temperature 
(1-2), Soil Temperature (1-4), Time, Transmitter Battery Status (ID# 
1-8), Repeater Battery Status (ID# A-H), Console Batteries, ISS 
Reception (% since midnight)
Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Greater Than or =, Less Than or =, Between, Not Between, True (or 
False, used for Barometer Trend and Battery Status Parameters), 
Trending, Equal, Minus (Difference), Missing (if data is dashed)