Gw Instek GPT-9801 Insulation measuring device, GPT-9801 Benutzerhandbuch

Produktcode
GPT-9801
Seite von 156
 
APPENDIX 
151 
RAMP (Ramp Time) 
0.1~999.9S 
TIMER (Test Time) 
1S~999.9S 
GND 
OFF 
 
Ground Bond Test 
Output Current Range 
03.00A~30.00A 
Output Current Accuracy 
 (1% of reading +0.2A) when 3A≤I≤8A 
 (1% of reading +0.05A) when 8A<I≤30A 
Output Current Resolution 
0.01A 
Frequency 
50Hz/60Hz 
Ohmmeter Measurement 
Accuracy 
 (1% of reading +2m
Ohmmeter Measurement 
Range 
10m
~650.0m
 
 
 
 
Test Voltage 
Max. 6V(AC) 
Ohmmeter Measurement 
Resolution 
0.1m
 
Windows Comparator Method  Yes 
TIMER (Test Time) 
0.5S~999.9S 
GND 
OFF 
 
Interface 
REMOTE (Remote terminal)  Yes 
SIGNAL IO 
Yes 
RS232 
Yes 
USB (Device) 
Yes 
GPIB 
Yes (OPTION) 
 
General 
DISPLAY 
240 x 64 dot matrix LED back light LCD 
MEMORY 
AUTO/MANU mode 100 memory blocks total 
Continued…