Texas Instruments Development Kit for TM4C129x,Tiva™ ARM® Cortex™ -M4 Microcontroller DK-TM4C129X DK-TM4C129X Datenbogen

Produktcode
DK-TM4C129X
Seite von 2182
Description
Reset
Type
Name
Bit/Field
3rd Sample Input Select (Upper Bit)
The
EMUX2
field is used during the third sample of a sequence executed
with the sample sequencer. This bit has the same description as
EMUX3
.
0x0
RW
EMUX2
8
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0
RO
reserved
7:5
2th Sample Input Select (Upper Bit)
The
EMUX1
field is used during the second sample of a sequence
executed with the sample sequencer. This bit has the same description
as
EMUX3
.
0x0
RW
EMUX1
4
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0
RO
reserved
3:1
1st Sample Input Select (Upper Bit)
The
EMUX0
field is used during the first sample of a sequence executed
with the sample sequencer. This bit has the same description as
EMUX3
.
0x0
RW
EMUX0
0