Texas Instruments Development Kit for TM4C129x,Tiva™ ARM® Cortex™ -M4 Microcontroller DK-TM4C129X DK-TM4C129X Datenbogen

Produktcode
DK-TM4C129X
Seite von 2182
Description
Reset
Type
Name
Bit/Field
4th Sample and Hold Period Select
The TSH3 field is used during the fourth sample of a sequence executed
with the sample sequencer.
0x0
RW
TSH3
15:12
3rd Sample and Hold Period Select
The TSH2 field is used during the third sample of a sequence executed
with the sample sequencer.
0x0
RW
TSH2
11:8
2nd Sample and Hold Period Select
The TSH1 field is used during the second sample of a sequence
executed with the sample sequencer.
0x0
RW
TSH1
7:4
1st Sample and Hold Period Select
The TSH0 field is used during the first sample of a sequence executed
with the sample sequencer.
0x0
RW
TSH0
3:0
December 13, 2013
1288
Texas Instruments-Advance Information
Analog-to-Digital Converter (ADC)