Cortex-M3 Processor Registers
2.7.4.6
STCR Register (Offset = 1Ch) [reset = X]
STCR is shown in
and described in
.
SysTick Calibration Value Used to enable software to scale to any required speed using divide and
multiply.
Figure 2-76. STCR Register
31
30
29
28
27
26
25
24
NOREF
SKEW
RESERVED
R-1h
R-1h
R-X
23
22
21
20
19
18
17
16
TENMS
R-75300h
15
14
13
12
11
10
9
8
TENMS
R-75300h
7
6
5
4
3
2
1
0
TENMS
R-75300h
Table 2-102. STCR Register Field Descriptions
Bit
Field
Type
Reset
Description
31
NOREF
R
1h
Reads as one. Indicates that no separate reference clock is
provided.
30
SKEW
R
1h
Reads as one. The calibration value is not exactly 10ms because of
clock frequency. This could affect its suitability as a software real
time clock.
29-24
RESERVED
R
X
Software should not rely on the value of a reserved. Writing any
other value than the reset value may result in undefined behavior.
23-0
TENMS
R
75300h
An optional Reload value to be used for 10ms (100Hz) timing,
subject to system clock skew errors. The value read is valid only
when core clock is at 48MHz.