Insys GSM Small 11-02-01-03-02.001 Benutzerhandbuch

Produktcode
11-02-01-03-02.001
Seite von 57
6. Function Description 
27 
6 Function Description 
6.1 Data 
Connection 
6.1.1 General 
ATD22243 
Dial number to which a connection is to be set up (always 
with dialing code, except for special provider numbers). 
CONNECT 9600/RLP
 
The call is accepted. The data is exchanged over the GSM 
network. 
+++
 
Changing from data mode to online AT command mode. 
Before and after this “Escape sequence”, there must be one 
second message “Silent” on the TXD line to the INSYS GSM 
small.  
The connection still remains, but no characters are 
transmitted to the other modem anymore. 
ATH
 
Hang up (terminate connection to the other party) 
or 
ATO
 
Return to data mode 
 
NO CARRIER
 
The other party has terminated the connection 
 
6.1.2  Connection to ISDN TAs 
To call an ISDN TA it is necessary to change to the ISDN protocol V.110. While doing so it 
must be observed that the remote terminal has to work with the same protocol as well. 
Example for V.110 with a data rate of 9600 bps:  AT+CBST=71,0,1 
6.1.3 Connection Acceptance 
The connection acceptance for incoming calls takes place either automatically with 
ATS0=x 
or manually by entering ATA after a RING.  
6.1.4 Disconnection 
Connections can be terminated as follows: 
 
•  Manually by the ATH command in online command mode 
•  If the remote terminal hangs up 
•  By DTR drop 
Version  1.00 / 09.04