Gw Instek PEL-3111 Electronic Load PEL-3111 Datenbogen

Produktcode
PEL-3111
Seite von 174
 
 
PEL-3000 Programming Manual 
70
 
Current Subsystem Commands 
 
 
:CURRent[:VA] ..................................................................... 70 
:CURRent:VB ........................................................................ 71 
:CURRent:SRATe ................................................................. 71 
:CURRent:L1 ......................................................................... 72 
:CURRent:L2 ......................................................................... 72 
:CURRent:SET ...................................................................... 73 
:CURRent:LEVel .................................................................. 74 
:CURRent:RISE .................................................................... 74 
:CURRent:FALL ................................................................... 75 
:CURRent:T1 ......................................................................... 75 
:CURRent:T2 ......................................................................... 76 
:CURRent:FREQuency ........................................................ 77 
:CURRent:DUTY ................................................................. 77 
 
:CURRent[:VA] 
Set
Query
 
 
Description 
Sets or queries the CC mode “A Value” (static 
mode) current. This command is applicable to 
static modes. 
Note: A different current value can be set for each 
current range (High/Mid/Low).   
 
Note: The [:VA] node can only be omitted when in 
static mode.
 
Syntax 
:CURRent[:VA] {<NRf>[ A ] | MINimum | MAXimum } 
Query Syntax 
:CURRent[:VA]? 
Parameter  
<NRf>[A] 
“A Value” current value 
 
MINIMUM or MIN 
Minimum current level 
 
MAXIMUM or MAX 
Maximum current level 
Return parameter  <NR2> 
Returns the “A Value” 
current value. 
Example 
:CURRent:VA MIN 
Sets the current value to the minimum.