Gw Instek PEL-3111 Electronic Load PEL-3111 Datenbogen

Produktcode
PEL-3111
Seite von 174
 
 
PEL-3000 Programming Manual 
72
 
Return parameter  <NR2> 
Returns the slew rate in 
mA/us. 
Example 
:CURRent:SRATe MIN 
Sets the slew rate to the minimum. 
Query example 
:CURRent:SRATe? 
>5.0 
Returns the slew rate as 5.0mA/us. 
:CURRent:L1 
Set
Query
 
 
Description 
Sets or queries the CC mode “Level 1” current. 
This command is only applicable to dynamic 
modes. 
Note: A different current value can be set for each 
range (High/Mid/Low).   
Syntax 
:CURRent:L1 {<NRf>[ A ] | MINimum | MAXimum } 
Query Syntax 
:CURRent:L1? 
Parameter  
<NRf>[A] 
“Level1” current value 
 
MINIMUM or MIN 
Minimum current level 
 
MAXIMUM or MAX 
Maximum current level 
Return parameter  <NR2> 
Returns the “Level1” 
current value. 
Example 
:CURRent:L1 MIN 
Sets the current value to the minimum. 
Query example 
:CURRent:L1? 
>1.0A 
Returns the “Level1” current setting. 
:CURRent:L2 
Set
Query
 
 
Description 
Sets or queries the CC mode “Level2” current. This 
command is only applicable to dynamic modes. 
Note: A different current value can be set for each 
range (High/Mid/Low).