Intel R2000BB4GS9 Datenbogen

Seite von 89
Intel
®
 Server System R2000BB Product Family TPS 
 
Revision 2.0 
 
 
 
53 
F – System Status LED – The System Status LED is a bi-color (Green/Amber) indicator that shows the 
current health of the server system. The system provides two locations for this feature; one is located on the 
Front Control Panel, the other is located on the back edge of the server board, viewable from the back of the 
system.  Both LEDs are tied together and will show the same state. The System Status LED states are driven 
by the on-board platform management sub-system.  The following table provides a description of each 
supported LED state. 
 
Table 24. System Status LED State Definitions 
Color 
State 
Criticality 
Description 
Off 
System is not 
operating 
Not ready 
System is powered off (AC and/or DC). 
System is in EuP Lot6 Off Mode. 
System is in S5 Soft-Off State. 
System is in S4 Hibernate Sleep State. 
Green 
Solid on 
Ok 
Indicates that the System is running (in S0 State) and its status is ‘Healthy’. 
The system is not exhibiting any errors. AC power is present and BMC has 
booted and manageability functionality is up and running. 
Green 
~1 Hz blink 
Degraded - system 
is operating in a 
degraded state 
although still 
functional, or 
system is operating 
in 
a redundant state 
but with an 
impending failure 
warning 
 
System degraded: 
Redundancy loss, such as power-supply or fan. Applies only if the 
associated platform sub-system has redundancy capabilities. 
Fan warning or failure when the number of fully operational fans is more 
than minimum number needed to cool the system. 
Non-critical threshold crossed – Temperature (including HSBP temp), 
voltage, input power to power supply, output current for main power rail 
from power supply and Processor Thermal Control (Therm Ctrl) sensors. 
Power supply predictive failure occurred while redundant power supply 
configuration was present. 
Unable to use all of the installed memory (one or more DIMMs 
failed/disabled but functional memory remains available) 
Correctable Errors over a threshold and migrating to a spare DIMM 
(memory sparing). This indicates that the user no longer has spared 
DIMMs indicating a redundancy lost condition. Corresponding DIMM LED 
lit. 
Uncorrectable memory error has occurred in memory Mirroring Mode, 
causing Loss of Redundancy. 
Correctable memory error threshold has been reached for a failing DDR3 
DIMM when the system is operating in fully redundant RAS Mirroring 
Mode. 
Battery failure. 
BMC executing in uBoot. (Indicated by Chassis ID blinking at Blinking at 
3Hz). System in degraded state (no manageability). BMC uBoot is running 
but has not transferred control to BMC Linux. Server will be in this state 6-8 
seconds after BMC reset while it pulls the Linux image into flash 
BMC booting Linux. (Indicated by Chassis ID solid ON). System in 
degraded state (no manageability). Control has been passed from BMC 
uBoot to BMC Linux itself. It will be in this state for ~10-~20 seconds. 
BMC Watchdog has reset the BMC. 
Power Unit sensor offset for configuration error is asserted. 
HDD HSC is off-line or degraded. 
Amber 
~1 Hz blink 
Non-critical - 
System is operating 
in a degraded state 
with an impending 
failure warning, 
although still 
functioning 
 
Non-fatal alarm – system is likely to fail: 
Critical threshold crossed – Voltage, temperature (including HSBP temp), 
input power to power supply, output current for main power rail from power 
supply and PROCHOT (Therm Ctrl) sensors. 
VRD Hot asserted. 
Minimum number of fans to cool the system not present or failed 
Hard drive fault 
Power Unit Redundancy sensor – Insufficient resources offset (indicates 
not enough power supplies present) 
In non-sparing and non-mirroring mode if the threshold of correctable 
errors is crossed within the window 
Correctable memory error threshold has been reached for a failing DDR3 
DIMM when the system is operating in a non-redundant mode