Intel R2000BB4GS9 Datenbogen

Seite von 89
Intel
®
 Server System R2000BB Product Family TPS 
54 
 
Revision 2.0 
Color 
State 
Criticality 
Description 
Amber 
Solid on 
Critical, non-
recoverable – 
System is halted 
Fatal alarm – system has failed or shutdown: 
CPU CATERR signal asserted 
MSID mismatch detected (CATERR also asserts for this case). 
CPU 1 is missing 
CPU Thermal Trip 
No power good – power fault 
DIMM failure when there is only 1 DIMM present and hence no good 
memory present
1
Runtime memory uncorrectable error in non redundant mode. 
DIMM Thermal Trip or equivalent 
SSB Thermal Trip or equivalent 
CPU ERR2 signal asserted 
BMC\Video memory test failed. (Chassis ID shows blue/solid-on for this 
condition) 
Both uBoot BMC FW images are bad. (Chassis ID shows blue/solid-on for 
this condition) 
240VA fault  
Fatal Error in processor initialization: 
Processor family not identical 
Processor model not identical 
Processor core/thread counts not identical 
Processor cache size not identical 
Unable to synchronize processor frequency 
Unable to synchronize QPI link frequency 
 
  
G – Power/Sleep Button – Toggles the system power on and off.  This button also functions as a sleep button 
if enabled by an ACPI compliant operating system. Pressing this button will send a signal to the iBMC, which 
will either power on or power off the system.  The integrated LED is a single color (Green) and is capable of 
supporting different indicator states as defined in the following table. 
Table 25. Power/Sleep LED Functional States 
State 
Power Mode 
LED 
Description 
Power-off 
Non-ACPI 
Off 
System power is off, and the BIOS has not initialized the chipset. 
Power-on 
Non-ACPI 
On 
System power is on 
S5 
ACPI 
Off 
Mechanical is off, and the operating system has not saved any context 
to the hard disk. 
S4 
ACPI 
Off 
Mechanical is off. The operating system has saved context to the hard 
disk. 
S3-S1 
ACPI 
Slow blink
1
 
DC power is still on. The operating system has saved context and 
gone into a level of low-power state. 
S0 
ACPI 
Steady on 
System and the operating system are up and running. 
 
H- Drive Activity LED - The drive activity LED on the front panel indicates drive activity from the on-board 
hard disk controllers.  The server board also provides a header giving access to this LED for add-in controllers.