1939STB4600 Manual 
 
 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Commercial  Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445 
 
RS-232 Baud Change 
 
Setting byte-3/nibble-2 to 2 and byte-4/nibble-1 to 2 causes the 1939STB 
to change baud. This function also requires 3 bytes of additional information 
bytes 5, 6, and 7. It is important to note that after a baud change the PC must 
have its baud changed to match the baud of the 1939STB for communication 
to exist. If communication is lost after a baud change and cannot be 
recovered, disconnecting the 1939STB from its power source will restore the 
1939STB to its default baud rate of 9600 baud, 1 stop bit, 8 data bits, no 
parity.   
 
Table 11.  Baud Rate Setup 
             Byte 3 
             Byte 4 
Byte 5 
Byte 6 
Byte 7 
Byte 
  1 
Byte 
  2 
Nibble 2 
Nibble 1 
Nibble 2 
Nibble 1 
UB3 
Baud 1 
Baud 2 
  81 
 21 
0010           0011 
    0000     
0010 
 
 
 
  81 
 21 
             23 hex 
           02 hex 
03 hex 
00 hex 
06 hex 
 
Table 11 shows how an internal command is used to set the 1939STB to a 
baud rate of 300, 1 stop bit, 8 data words, and no parity. Byte 3 nibble 2 sets 
the internal command function. A nibble value of 2 sets the J1939STB into 
the Internal Function mode. Nibble 1 of byte 3 tells the 1939STB 3 bytes will 
follow Byte 4. Byte 4, nibble 1 is set to 2 telling the 1939STB to perform a 
baud change using the information contained in bytes 5, 6, and 7. 
 
Table 12.  Baud Rate Setup 
Baud Rate 
Decimal Divisor 
Hex Divisor  MSB (Baud 2) 
Hex Divisor LSB (Baud 1) 
300 
1556 
06 hex 
00 hex 
1200 
384 
01 hex 
80 hex 
2400 
192 
00 hex 
C0 hex 
9600 
48 
00 hex * 
30 hex * 
19200 
24 
00 hex 
18 hex 
38,400 
12 
00 hex 
0C hex 
57,600 
00 hex 
08 hex 
* Setup default value.