Starting Address Hi 00  
Starting Address Hi 00 
Starting Address Lo 01  
Starting Address Lo 01 
Quantity of Registers Hi 00  
Quantity of Registers Hi 00 
Quantity of Registers Lo 02  
Quantity of Registers Lo 02 
Byte Count 04 
CRC 1008 
Registers Value Hi 00 
 
Registers Value Lo 0A 
 
Registers Value Hi 01 
 
Registers Value Lo 02 
 
CRC 9230 
 
Table 12:  Modbus Function 16 – Example 
 
 
7.4.4  Diagnostics (0x08) (Loopback) 
 
Request & Response message: 
SLAVE ADDRESS + FUNCTION CODE + SUB-FUNCTION CODE + DATA + 
CRC 
 
Request 
 
Length Valid 
Value 
Slave Address 
1 Byte  
0 to 247 
Function code  
1 Byte  
0x08 
Sub-function 2 
Bytes 
0x00  
Data Any 
 value 
CRC  
0x0000 to 0xFFFF 
Table 13:  Modbus Function 08 - Request & Response Message 
 
An exact copy of the diagnostic query message is sent back as a response. 
 
Connections 
 
The XVG/eXVG can communicate via RS-232 or RS-485, one interface or the other. 
To communicate with an XVG/eXVG that was built with RS-485 interface circuit, you 
may need to use RS232-to-RS485 converter. 
The connection from the PC or PLC’s serial port to the XVG/eXVG can be made as 
follows: 
 
 
 
 
 
 
 
 
 10