Make Gas Connection
Typical rigid pipe connection
A combination of pipe fittings must be used to connect the range 
to the existing gas line. Your connections may be different, 
according to the supply line type, size and location.
1. Apply pipe-joint compound made for use with LP gas to all 
pipe thread connections.
2. Using a pipe wrench to tighten, connect the gas supply to the 
range.
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the 
smaller thread ends of the flexible connector adapters (see B 
and F in the following illustration).
2. Attach one adapter to the gas pressure regulator and the 
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a combination wrench and pliers to attach the flexible 
connector to the adapters. Check that connector is not kinked. 
Complete Connection
1. Locate gas pressure regulator in the broiler.
IMPORTANT: Do not remove the gas pressure regulator.
2. Check that the gas pressure regulator shutoff valve is in the 
“ON” position.
3. Open the manual shutoff valve in the gas supply line. The 
valve is open when the handle is parallel to the gas pipe.
4. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. Bubbles will show a 
leak. Correct any leak found.
A. Pressure regulator 
connection fitting
B. 90° elbow
C. Black iron pipe
D. Union
E. Nipple
F. Manual shutoff valve
G. ½" or ¾" gas pipe
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
G
E
F
C
D
A
B
A. Pressure regulator 
connection fitting
B. Use pipe-joint compound.
C. Adapter
D. Flexible connector
E. Adapter
F. Use pipe-joint compound.
G. Manual shutoff valve
H. ½" or ¾" gas pipe
A. Gas pressure regulator
A. Closed valve
B. Open valve
C
E
G
H
A
D
F
B
A
Front View
Front View
Side View
Shutoff valve
Front
“ON” Position
A