Viking CTG-1 Benutzerhandbuch

Seite von 4
500
Hz
500
Hz
500
Hz
.6
sec
.6
sec
.6
sec
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no respon-
sibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.
Fax Back Doc 460
ZF300500 Rev F
Printed in the U.S.A.
A. Bong Alert Tone
B. Buzzer Alert Tone
E. Siren (Yelp)
S
S
o
o
u
u
n
n
d
d
O
O
u
u
t
t
p
p
u
u
t
t
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
On
Off
On
Off
On
Off
300 ms
300 ms
300 ms
280 Hz
2270 Hz
280 Hz
2270 Hz
3 sec
60 Hz
Single
.8 sec
60 Hz
Double
60 Hz
.8 sec
.8 sec
60
Hz
60
Hz
60
Hz
500 Hz
3 sec
500 Hz
3 sec
500 Hz
3 sec
1 sec
1 sec
1 sec
Single
Double
Triple
3 second break
then repeated
a second time
3 second break
then repeated
a second time
Continuously repeated while pin 11 is shorted to pin 12.
O
O
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
When the clock time matches an event time and that day is set to “ON” or “A”, the CTG-1 will output the corresponding single, double or
triple bong or buzzer alert tone.  The CTG-1 will also open terminals 3 and 4 (normally closed) and close terminals 4 and 5 (normally
open), allowing the capability of switching out the audio from the phone system and switching in the alert tone from the CTG-1.  Similarly,
while a contact closure is made shorting pins 9, 10 or 11 to pin 12, the CTG-1 will output the corresponding sound (doorbell, evacuation
signal or emergency siren).  In the case of the siren or evacuation signal, terminals 3 and 4 will open, and terminals 4 and 5 will close
and the sound will continue for the duration of the contact closure input. Terminals 3, 4 and 5 will return to their normal states at the end
of each doorbell tone. Note: Terminals 6, 7 and 8 will operate the same as terminals 3, 4 and 5 but are electronically isolated from ter-
minals 3, 4 and 5 for switching a separate device.
IMPORTANT:  While operating, the CTG-1 continuously checks the event time information stored in memory.  If a problem is detected,
the CTG-1 displays “EEE” to indicate an error.  Normal clock function continues in the background.  To clear the error, press any button
and the CTG-1 will return to normal operation.  If the “EEE” display persists, contact Viking Technical Support at 715-386-8666.
Triple
840 Hz
C. Doorbell (Ding Dong)
On
Off
.3 sec
3 sec
500 Hz
One per closure across pin 9 and pin 12.
D. Evacuation Signal (Temporal Slow Whoop)
On
Off
.5 sec
.5 sec
.5 sec
.5 sec
1.5 second
Break
200 Hz
700 Hz
Continuously repeated while pin 10 is shorted to pin 12.
J. DIP Switch Settings
S1
1 2
on
1
2
ON
ON
OFF
Internal View of the CTG-1
Switch
1
1
2
2
Position
OFF
ON
OFF
ON
Description
Battery backup disabled
Battery backup enabled 
Bong alert tones (factory setting)
Buzzer alert tones 
.5 sec
P
P
r
r
o
o
d
d
u
u
c
c
t
t
S
S
u
u
p
p
p
p
o
o
r
r
t
t
L
L
i
i
n
n
e
e
.
.
.
.
.
.
7
7
1
1
5
5
.
.
3
3
8
8
6
6
.
.
8
8
6
6
6
6
6
6
F
F
a
a
x
x
B
B
a
a
c
c
k
k
L
L
i
i
n
n
e
e
.
.
.
.
.
.
7
7
1
1
5
5
.
.
3
3
8
8
6
6
.
.
4
4
3
3
4
4
5
5