Additive Feeders 
Chapter 4: Operation 
31 of 50 
Additive Feeder Control Factory Defaults 
WARNING!  This procedure involves resetting a DIP switch within a live electrical 
enclosure.  Only persons with the proper knowledge of and respect for 
working on energized electrical devices should attempt this procedure.  Use 
extreme caution!  
 
Note: 
Set the decimal point with DIP switch 4 first to avoid confusion when 
keying in the presets; for example, 300 and 30.0.
 
Figure 4:  Additive Feeder Control Factory Defaults 
DIP Variable 
Pre-set 
Switch 1 
Auger RPM Constant 
30.0 
Switch 2 
Program Minimum 
0.0 
Switch 3 
Program Maximum 
70.0 
Switch 4 
Decimal Place 
0.3 
Master/Follower Select 
Standard Control 
OFF 
Switch 5 
Optional Extruder 
Tracking Control 
ON 
 
4-3  Shutting Down the Additive Feeder 
1.  Flip the motor switch to the OFF (center) position. 
2.  Turn the power OFF
For long term shutdown, disconnect power and clean the additive feeder.