Hoshizaki MODULAR CRESCENT CUBER SERENITY SERIES KMS-1400MLH Benutzerhandbuch

Seite von 56
36
Problem
Possible Cause
Remedy
[1] The icemaker will not 
start.
a) Power Supply 
(Condensing Unit)
1. Off, blown fuse, or 
tripped breaker.
1. Turn on, replace, or reset.
. Loose connections.
. Tighten.
3. Bad contacts.
3. Check for continuity and 
replace.
4. Not within 
specifications.
4. Refer to nameplate and  
correct.
b) Water Supply
1. Water supply off or 
pressure too low.
1. Check and get 
recommended pressure.
c) High Pressure Control 1. Open contacts.
1. Check for continuity, let 
reset or replace.
. Dirty condenser coil.
. Clean.
3. Refrigerant 
overcharged.
3. Recharge.
4. Fan not operating.
4. See chart 1.[6]
5. Refrigerant line or 
components plugged.
5. Clean and replace drier.
d) Thermostat 
(Condensing Unit High 
Temperature Safety)
1. Open contacts.  
1. Let cool and reset. Check 
for continuity and replace 
if open.
e) Wire Harness Terminal 
Block: Condensing Unit 
and Icemaker
1. Loose connection.
1. Tighten.
f) Fuse (Icemaker fused 
disconnect, if any)
1. Blown.
1. Check for short circuit and 
correct. Reset or replace.
g) Fuse (10A fuse in 
icemaker)
1. Blown.
1. Check for short circuit and 
replace.
h) Control Switch
1. "OFF" position.
1. Move to "ICE" position.
. Bad contacts.
. Check for continuity and 
replace.
3. Loose connection.
3. Tighten.
i) Transformer
1. Open windings.
1. Replace.
j) Bin Control
1. Tripped with bin filled 
with ice.
1. Remove ice.
. Proximity switch stuck 
open.
. Replace bin control.
k) Wiring to Control Board 1. Loose connections or 
open.
1. Check for continuity and 
replace.
B. Diagnostic Charts
1. No Ice Production