Hoshizaki MODULAR CRESCENT CUBER SERENITY SERIES KMS-1400MLH Benutzerhandbuch

Seite von 56
39
2. Evaporator is Frozen Up
Problem
Possible Cause
Remedy
[1]Freeze cycle time is 
too long.
a)Float Switch
1. Leads short-circuit or 
defective switch.
1. Check and replace.
. Float does not move 
freely.
. Clean or replace.
b)Fill or Harvest Water  
Valve
1. Diaphragm does not 
close.
1. Check for water leaks.
c) Control Board
1. Defective.
1. See "II.C.4. Control Board 
Check Procedure".
[]All ice formed on 
evaporator does not 
fall into bin in harvest 
cycle.
a)Evaporator
1. Scaled up.
1. Clean.
b)Water Supply Line
1. Water pressure too 
low.
1. Check and get 
recommended pressure.
c) Water Filter System
1. Dirty/restricted.
1. Replace filter.
d)Harvest Water Valve
1. Dirty mesh filter or 
orifice.
1. Clean.
. Diaphragm does not 
close.
. Check for water leaks.
e) Ambient and/or Water 
Temperature
1. Too cool.
1. Increase temperature.
f) Liquid Line Valve
1. Continues to open in 
harvest cycle.
1. Check operation in harvest 
cycle and replace.
g)Thermistor
1. Out of position or 
loose attachment.
1. See "V.C.6. Removal 
and Replacement of 
Thermistor."
h)Control Board
1. Defective.
1. See "II.C.4. Control Board 
Check Procedure".
[3]Other
a)Spray Tubes
1. Clogged.
1. Clean.
. Out of position.
. Place in position.
b)Water System
1. Dirty.
1. Clean.
c) Refrigerant
1. Undercharged.
1. Check for leaks and 
recharge.
d)Expansion Valve
1. Bulb out of position or 
loose attachment.
1. Place in position.
. Defective.
. Replace.
e)Hot Gas Valve
1. Coil winding opened. 1. Replace.
. Plunger does not 
move.
. Replace.
3. Wiring to hot gas 
valve.
3. Check for loose 
connection or open, and 
replace.
f) Water Supply Line
1. Too small; requires 
1/" OD line dedicated 
per machine.
1. Increase water line size.
g)Water Filter  
1. Flow rate too small.
1. Replace with filter that has 
larger flow rate.