Problem
Possible Cause
Remedy
[1] Icemaker will not stop 
when bin is filled with 
ice.
a) Bin Control
1. Defective.
1. Replace.
b) Control Board
1. Defective.
1. See "II.C.4. Control Board 
Check Procedure".
[] Abnormal noise.
a) Pump Motor
1. Bearings worn out.
1. Replace.
b) Fan Motor
1. Bearings worn out.
1. Replace.
. Fan blade deformed.
. Replace fan blade.
3. Fan blade does not 
move freely.
3. Replace.
c) Compressor
1. Bearings worn out or 
cylinder valve broken.
1. Replace.
. Mounting pad out of 
position.
. Reinstall.
d) Refrigerant Lines
1. Rub or touch other 
lines or surfaces.
1. Reposition.
[3] Ice in storage bin 
often melts.
a) Bin Drain
1. Plugged.
1. Clean.
b) Icemaker and Bin
1. Drains not run 
separately.
1. Separate the drain lines.
4. Abnormal Ice
Problem
Possible Cause
Remedy
[1] Small cubes.
a) Ice Cube Guide or Ice 
Separator
1. Out of position. 
Circulated water falls 
into bin.
1. Place in position.
b) See chart 1.[5] and check water supply line, water valves, water system, pump 
motor, and control board.
c) Drain Water Valve
1. Leaking.
1. Check and replace.
[] Cloudy or irregular 
cubes.
a) See chart .[1] and .[3], and check float switch, water valves, control board, 
spray tubes, water system, refrigerant charge, and expansion valve.
b) Spray Guide
1. Dirty.
1. Clean.
c) Water Quality
1. High hardness or 
contains impurities.
1. Install a water softener or 
filter.
3. Low Ice Production
Problem
Possible Cause
Remedy
[1] Freeze cycle time is 
long.
a) See chart 1.[3]. Also check dirty condenser coil, ambient temperature and 
refrigerant charge.
b) See chart .[1] and check float switch, water valves and control board.
[] Harvest cycle time is 
long.
a) See chart .[] and check evaporator, water supply line, harvest water valve, 
ambient and/or water temperature, liquid line valve, thermistor, and control 
board.
5. Other