Fairchild CAM/CMOS-2K.LS Benutzerhandbuch

Seite von 42
Table 2.2.1 
Camera Pin # 
Frame Grabber Pin # 
Channel Link Signal 
1 1 Inner 
shield 
14 14  Inner 
shield 
2 25 
X0 
15 12 
X0+ 
3 24.0 
X1- 
16 11 
X1+ 
4 23 
X2- 
17 10 
X2+ 
5 22 
Xclk 
18 9 
Xclk+ 
6 21 
X3 
19 8 
X3+ 
7 20  SerTC+ 
20 7 
SerTC- 
8 19  SerTFG- 
21 6  SerTFG+ 
9 18 
CC1- 
22 5 
CC1+ 
10 17 
CC2- 
23 4 
CC2+ 
11 16 
CC3- 
24 3 
CC3+ 
12 15 
CC4- 
25 2 
CC4+ 
13 13  Inner 
shield 
26 26  Inner 
shield 
 
Notes: 
•  Exterior overshield is connected to the shells of the connectors on both ends. 
•  3M part 14X26-SZLB-XXX-0LC is a complete cable assembly, including connectors. 
•  Unused pairs should be terminated in 100 ohms at both ends of the cable. 
 
2.3  Power Supply 
•  The camera uses a single voltage input, normally set to 5.0V. 
•  Ripple and noise is required to be < 20 mV RMS. 
•  Power is supplied through a Hirose connector.  
•  When installing the mating connector, be sure to line up the slots.  This action will assure that 
you will not bend any of the pins. 
Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev C• 12 of 42