Fairchild CAM/CMOS-2K.LS Benutzerhandbuch
Table
2.3.1
Hirose Receptacle
Pin #
Description
1
+5.0 - +6.0 V DC
2
+5.0 – +6.0V DC
3 Ground
4 Ground
If you are using an adjustable lab power supply it is extremely important that
you apply the apppropriate voltage to your camera. Incorrect voltage might damage
the camera.
the camera.
Figure 2.3.1
Back View of CAM/CMOS – 2K.LS
2.4 LED Indicator Status Lamp
Table 2.4.1
Light Color
Status
Green Running
Blinking Amber/Red
Busy with command
Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev C• 13 of 42