10 
635/636 CONTROL BOARD CONNECTIONS 
 
Emergency Bypass Connector 
 
Used when the control board is not functioning. Unplug the 
motor harness from the Master (or Slave) Connector and 
momentarily insert into the Emergency Bypass Connector to 
open the gate. In the event the motor is not disconnected 
quickly enough, the blue 15 amp fuse will protect the circuit 
board from damage and should be replaced when the 
original problem is fixed. 
8 Pin White Connector (two on 636 Master & Slave) 
7 Pin Black Connectors  
1 Edge 1 Input 
2 Edge 2 Input 
3 Ground 
4 Ground 
5 Stop Input (N/C) 
6 Close Input (N/O)       
7 Open Input (N/O) 
8 Ground 
9 Ground 
10 Free Exit 
Input (Open only for telephone entry, probes, etc.) 
11 Ground 
12 Under Gate or Shadow Loop 
Input  
13 Ground 
14 Safety Loop or Photo Beam 
Input 
 
3 Pin Black Connectors (3) 
 
GND  Ground 
INP    Input (Activates gate when momentarily connected to ground) 
12V   +12 Volt Output (For powering options - 3 Amps Max.) 
1 ORANGE - Open Limit Input (Normally open unless gate is opened) 
2 WHITE - Close Limit Input (Normally open unless gate is closed) 
3 BLACK - Motor - Positive during open cycle, Negative during close cycle  
4 RED - Motor - Negative during open cycle, Positive during close cycle  
5 GREEN - Ground (Limit Switch Common)  
6 Ground Not used 
 
7 BLACK - Ground -
 Battery Negative  
8 RED - Battery Positive (+12 VDC)  

 
 

 
 

 
 

 
 

 
 

 
 
MASTER 
123
 
3 Button Control