J23: Watchdog Output  
This connector allows the user to send Ohm output from the Turbo Clipper Drive to the machine 
if a watchdog condition has occurred. This is an important safety feature because the Clipper 
Amp is totally disabled when it is in watchdog condition and this output will allow the other 
machine’s hardware/logic to bring the process to a safe condition. In normal operation there is 5 
volts between pin 1 and 2 and in the time of watchdog this will drop to zero.  
 
J21: Molex (M) 
Molex Mating Connector Part #: 22-01-3027 (F)  
Molex Crimper Pin Part #: 08-50-0114 
 
For Internal Use: 
DT Part #: 014-000R02-LHM 
DT Part #: 025-500114-PNM 
 
Pin # 
Symbol 
Function  Description 
+5V_5A 
Output 
5 volts in normal operation  
B_WDO 
Output 
Ground