Delta Tau TURBO CLIPPER DRIVE 用户手册
Turbo Clipper Drive User Manual
Breakout Board: Wiring, Software Setup
29
J23: Watchdog Output
This connector allows the user to send Ohm output from the Turbo Clipper Drive to the machine
if a watchdog condition has occurred. This is an important safety feature because the Clipper
Amp is totally disabled when it is in watchdog condition and this output will allow the other
machine’s hardware/logic to bring the process to a safe condition. In normal operation there is 5
volts between pin 1 and 2 and in the time of watchdog this will drop to zero.
if a watchdog condition has occurred. This is an important safety feature because the Clipper
Amp is totally disabled when it is in watchdog condition and this output will allow the other
machine’s hardware/logic to bring the process to a safe condition. In normal operation there is 5
volts between pin 1 and 2 and in the time of watchdog this will drop to zero.
J21: Molex (M)
Molex Mating Connector Part #: 22-01-3027 (F)
Molex Crimper Pin Part #: 08-50-0114
For Internal Use:
DT Part #: 014-000R02-LHM
DT Part #: 025-500114-PNM
Molex Mating Connector Part #: 22-01-3027 (F)
Molex Crimper Pin Part #: 08-50-0114
For Internal Use:
DT Part #: 014-000R02-LHM
DT Part #: 025-500114-PNM
Pin #
Symbol
Function Description
1
+5V_5A
Output
5 volts in normal operation
2
B_WDO
Output
Ground