Barco Projector 26-0313000-00 Benutzerhandbuch
Encore Presentation System • User’s Guide • Rev 04
395
aK==tçêâáåÖ=táíÜ=aÉëíáå~íáçåë
ScreenPRO-II Configurations
bñíÉêå~ä=pÉêá~ä=oçìíÉê=`çåÑáÖìê~íáçå
The diagram below shows a configuration that uses two ScreenPRO-II units with external
source routing. Each ScreenPRO-II is set up as a unique destination.
source routing. Each ScreenPRO-II is set up as a unique destination.
In this configuration, two external serial (RS-232) routers are used — one for analog
connections and one for SDI source connections to each ScreenPRO-II. Because two
serial connections are required, a Lantronix UDS200 is used.
connections and one for SDI source connections to each ScreenPRO-II. Because two
serial connections are required, a Lantronix UDS200 is used.
Figure D-2. ScreenPRO-II units using external serial controlled routers
For an “external routing” configuration with serial controlled routers, please note the
following points regarding destination setup and source connections:
following points regarding destination setup and source connections:
•
On the Destination Setup Menu:
~
Select Single Screen SP as the “Type.”
~
Set the “Routing Mode” to External.
~
In Chapter 6, refer to the “
page 279 for instructions.
•
Connect analog and digital sources to each router in the normal manner.
•
For each router, connect two outputs to each ScreenPRO-II.
•
On the Router Specification Menu, select the correct router and manufacturer,
and set the “Communication Type” to LANTRONIX. In Chapter 6, refer to the
“
and set the “Communication Type” to LANTRONIX. In Chapter 6, refer to the
“
” section on page 270 for instructions.
•
Router outputs are mapped using the Output Patch Menu. This menu defines
which router output connects to which ScreenPRO-II input. In Chapter 6, refer to
the “
which router output connects to which ScreenPRO-II input. In Chapter 6, refer to
the “
” section on page 270 for instructions.
•
Router inputs are mapped using the Input Patch Menu. In Chapter 6, refer to the
“
“
” section on page 285 for instructions.
MatrixPRO SDI Router
MatrixPRO Analog Router
RS-232
Lantronix
UDS200
Ethernet
Encore Controller (SC or LC)
ScreenPRO-II
Ethernet Switch
Side Screen 1
Side Screen 2
Router
Outputs
Inputs
RS-232
SDI
Inputs
Analog
Inputs