Configuring the Serial Interface 
Introduction
This section describes the serial interface and explains how to configure your 
Vanguard 342 for various communication interface types. These topics are 
discussed:
The Serial Interface  The Vanguard 342 supports a software-programmable serial interface that is integral 
to the motherboard. Port 3 supports the serial interface and can be configured to 
function as a fixed Data Interface Module, providing communication using these 
interface types:
• V.24
• V.35
• V.36
• X.21/V.11
Note
The serial interface supports only DCE mode but can accommodate DTE with 
the use of a crossover adapter cable. For information on DTE capability, refer to 
the “Setting the Interface Options” section on page 3-10.
The Serial Interface 
Parameters
The serial interface is supported in the Port Configuration menu and can be 
configured using the Control Terminal Port (CTP). Included in the Port 
Configuration menu, are two parameters that allow you to set both the 
communication and electrical interfaces. These parameters are:
Interface Type 
This parameter allows you to set the communication interface type (physical layer 
protocol) on Port 3. The interface types include: V.24, V.35, V.36, and X.21/V.11.
Interface Option
This parameter allows you to specify the traditional hardware strap used in V.24 
Vanguard Daughtercards and electrical interface for V.35, V.36, and X.21/V.11 
cabling operations.