Setting the Interface Options
Introduction
This section provides instruction for setting the Interface Options parameter.
V.24 Interface Type Use this procedure to set the Interface Options parameter for V.24 interface type:
Step
Action
Result/Description
1
From the Control Terminal Port 
Main menu, select Configure -> 
Port
.
The Port record appears.
2
In the Port Number parameter, 
type 3, then press ENTER.
Port 3 is selected.
3
In the Port Type parameter, type 
FRI, then press ENTER
This defines Port 3 type as FRI.
4
In the Interface Type parameter, 
type V.24, and then press 
ENTER.
The interface is set to V.24
5
In the Interface Options 
parameter, type a ?, and then 
press ENTER.
The Range and Default appears:
Range = RI, TM
Default = RI 
Specify the Pin 22 option:
RI - V.24 uses Pin 22 for Ring 
Indicator output signal
TM - V.24 uses Pin 22 for Test 
Mode input signal
6
Select either RI or TM for the 
Interface Option.
When RI is selected, the output signal 
is Ring Indicator.
When TM is selected, the input signal 
is Test Mode.