PLANNING
GUIDE
DR30D, DR30DH, DR30DI, DR30DIH
Distinctive 30” Wide 
Dual Fuel Range
Document # PG05-006
Revised 01/30/13   Page 2/6
ranges equipped for installation in Canada:
 
Freestanding ranges used in Canada require 
a factory installed 4-wire appliance cord and 
NEMA 14-50P plug. Order model number 
DR30D-C or DR30DH-C. The appliance cord is   
66 inch (168 cm) long.
 
Do not modify the factory wiring. The plug is 
designed to plug directly into a NEMA 14-50R 
electrical receptacle installed by a licensed 
electrician.
all other models:
The wiring needs to be long enough to allow the range to be pulled out for 
service, while remaining connected (see following page).
The wiring connected to the range must:
 
Meet NEMA standards and have a minimum rating of 250 Volts @ 30 
Amp.
 
Include a strain relief.
 
Be terminated by tinned leads, closed loop terminals or open ended 
spade lugs with upturned ends.
 
Connect to a junction box or receptacle installed by a licensed 
electrician.
Where local code permits, a 3 or 4 wire appliance cord may be used. It 
must:
 
Be UL listed type SRD or SRDT.
 
Be equipped with a NEMA 14-50P 4-wire plug or, where local code 
permits, a NEMA 10-50P 3-wire plug.
Electrical Specifications
Circuit required
Total Connected Load
240 Vac, 60 Hz., 30 Amp.*
5.7 kW (23.8 Amp.)
 
The ratings above are for reference only - refer to the range's product 
data label for exact specifications.
 
The correct voltage, frequency and amperage must be supplied to 
the appliance from a separate, grounded, circuit that is protected by a 
properly sized circuit breaker or time delay fuse. If a time-delay fuse is 
utilized, fuse both sides of the line (L1 and L2).
* Two 120 Vac hot (L1 and L2), one neutral, one ground
The regulator inlet accommodates a 3/4” gas line. The range ships with a 
1/2” to 3/4” adapter connected to the regulator.
gas and Electrical requirements
a
B
C
D
4 3/4”
(12.1 cm)
22 1/8”
(56.2 cm)
8 3/4”
(22.2 cm)
13 3/4”
(34.9 cm)
B
Gas 
inlet
A
C
7/8” (2.2 cm) dia. electrical 
connection hole in bottom*
D
Range electrical access, 
cover removed
GAs AND ELEctRIcAL DImENsIoNs
gas Supply Pressure requirements*
gas Type
Manifold Pressure
Minimum gas Supply 
Pressure
Natural gas
5” water column
6” water column
LP
10” water column
11” water column
* Maximum input gas supply pressure for all models is 1/2 psi
7/8" to 1 1/8" dia. access hole
NEmA 14-50R 
REcEPtAcLE
ovERALL DImENsIoNs - moDEL DR30DI[H] 
 WItH ERv3015 RAIsED vENt
Stiffener
Cabinet face*
Countertop*
*
IMPOrTaNT: See Countertop/Cabinet Cutout Dimensions for required countertop cutout dimensions.
There are three possible configurations.
**
IMPOrTaNT: If 3 1/4 inch side panels are removed, cabinet face must be flush with back of control panel.
Back of
control
panel
ERV3015
raised vent
DR30DI[H] range
3/8” min. (1.0 cm)
space behind
raised vent
chassis to clear
stiffener
3/8” min. (1.0 cm)
flat countertop
overhang required
behind cutout
3 1/4 inch
side panel**
Countertop height:
35 7/16" (90.0 cm) min.
37 7/16” (95.1 cm) max.
28 11/16” (72.9 cm)