PLANNING
GUIDE
DR30D, DR30DH, DR30DI, DR30DIH
Distinctive 30” Wide 
Dual Fuel Range
Document # PG05-006
Revised 01/30/13   Page 3/6
Note 3
Note 6
E
F
3
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of
cabinet front, see Product Dimensions.
4
Consult local code for exact location requirements.
6
Model DR30D[H]: 37 7/8 (96.2 cm) max.
Model DR30DI[H]: 37 7/16 (95.1 cm) max.
2
Distance to combustible surfaces measured from cooking
surface (top of cooktop grate); if installing an overhead
range hood, also check the hood specifications for minimum
required clearances.
1
Minimum distance to a combustible rear wall for model
DR30DI[H] is 2.5” (6.4 cm) from top rear trim. Model DR30D[H]
may be installed flush to rear wall, but non-combusible surface
or 9-inch backguard (PNADB3009) is recommended.
Back wall
1
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
30” (76.2 cm)
min.
2
13” (33.0 cm)
max.
5
18” (45.7 cm)
min.
2, 5
Suggested
location of
utilities
4
5
This specification does not apply for cabinets located
greater than a horizontal distance of 10” (25.4 cm)
from the edge of the range.
Cutout Dimensions
E
F***
36” (91.4 cm)*
30” (76.2 cm)**
30 
1
/
16
” (91.6 cm)
* Recommended     ** Minimum
*** See following page for model DR30DI[H]
gas and Electrical Service
 
The shaded area shown below denotes the location of the gas inlet 
and the electrical junction box/receptacle. This is the recommended 
location. For replacement purposes, the location of the existing 
utilities may be utilized provided they do not interfere with the sides 
or rear of the range. Check local building codes for permissible gas 
valve locations.
 
An external manual shut-off valve must be installed between the gas 
inlet and the range for the purpose of turning on or shutting off gas to 
the appliance.
The installation must allow for the following:
 
Access to the gas shut-off valve when the unit is installed. 
 
Access to the remote circuit breaker panel/fuse box when the range 
is in place.  
 
The gas supply piping, gas shut-off valve and the electrical junction 
box or receptacle must be located so they do not interfere with the 
range when it is installed.
 
The junction box and gas shut off valve must be located so that 
the range can be pulled out for service while the appliance remains 
connected. 
Cabinet Layout
 
Carefully check the location where the range is to be installed. For 
best performance, the range should be placed away from drafts that 
may be caused by doors, windows and heating and air conditioning 
outlets.
 
To reduce the risk of personal injury and to reduce accumulated 
smoke in the room, Dacor strongly recommends installing a range 
hood or raised vent (model DR30DI[H] only). A range hood should 
project horizontally a minimum of five (5) inches beyond the face of 
the cabinets.
 
All maximum and minimum dimensions and clearances shown in the 
diagram below must be maintained for safe operation.
 
Any openings in the wall behind the appliance or in the floor 
underneath it must be sealed. 
 
Carefully note the requirements stated below for clearances to walls 
and cabinets.
REqUIRED cAbINEt 
DImENsIoNs
Cabinet tolerances: -1/16”, (+1.6 mm) -0