LEVELING
2.  Grip dryer from top and rock back and forth, making sure all four 
legs are firmly on floor. Repeat, rocking dryer from side to side.  
If dryer rocks, go to Step 3 and adjust leveling legs.
3.  If dryer is not level, use a 1" or 25 mm open-end or adjustable 
wrench to turn the leveling leg counterclockwise to lower the 
dryer or clockwise to raise the dryer. Recheck levelness of dryer 
and that all four legs are firmly in contact with the floor. Repeat 
as needed.
HELPFUL TIP: You may want to prop up front of dryer about 4" 
(102 mm) with a wood block or similar object that will support 
weight of dryer.
1.  Check the electrical requirements. Be sure that you have the 
correct electrical supply and the recommended grounding 
method. See “Electrical Requirements.”
2.  Check that all parts are now installed. If there is an extra part,  
go back through the steps.
3.  Check that you have all of your tools.
4.  Dispose of/recycle all packaging materials.
5. Plug into a grounded outlet, or connect power.
6.  Check dryer operation:
Models with Electronic Display: 
Close dryer door. Set the cycle. Operating time will accumulate 
per number of coins.
Mechanical Models: 
Some accumulated time may be on the timer due to factory 
testing. Close dryer door. Turn timer-set knob to the right. 
(Operating time will accumulate per number of depressions and 
type of timing cam used.) Push START button. 
Using a full heat cycle (not the air cycle), let the dryer run for at 
least five minutes. Dryer will stop when time is used up. Make 
sure the dryer turns off.
NOTE: Dryer door must be closed for dryer to operate. When 
door is open, dryer stops, but timer continues to run. To restart 
dryer, close door and push START button (mechanical models 
only).
7.  Open the dryer door. Check that the inside of the dryer is warm. 
If the burner does not ignite and you can feel no heat inside the 
dryer, shut off dryer for five minutes. Check that all supply valve 
controls are in “ON” position and that the electrical cord  
is plugged in. Repeat five-minute test.
8.  If drying time is too long, make sure that the lint screen is clean 
and that there are no obstructions to airflow in the dryer vent 
system.
9.  Restart the dryer and allow it to complete a full heat cycle  
(not air cycle) to make sure it is working properly.
COMPLETE INSTALLATION