Blomberg DHP24412W Benutzeranleitung

Seite von 28
12 / 28  EN
Dryer / User Manual
Installation Instructions
3.4 Minimum Installation Clearances
Alcove or 
Built-under
Closet
Sides
0.59 in. (15 mm)
0.59 in. (15 mm)
Top
2.68 in. (68 mm)
2.68 in. (68 mm)
Rear
0.59 in. (15 mm)
0.59 in. (15 mm)
Front
0.20 in. (5 mm)
0.20 in. (5 mm)
Ventilation Requirements
Closet door must have 2 openings, one located 3.2 
inches (8 cm) from bottom of door having a minimum 
area of 16 sq. inches (103 cm2) and the other one 
located 3 inches (7.5 cm) from top of door having a 
minimum area of 46 sq. inches (294 cm2).
3.5 Use on top of a washing machine
• 
A stacking-kit (Part no: 298 530 0200) should be 
used between the two machines for use on top of 
a washing machine. The stacking-kit should be 
installed by the Authorized Service provider.
• 
Place the appliance on a solid floor. If it is to 
be placed on top of a washing machine, the 
approximate weight together may reach 397 lbs 
(180 kg) when they are full.  Therefore, the floor 
must be capable of carrying the load placed on it!
 90
0
 90
0
 
36.14
 
(918 mm)
min.
 25 ¾
 650 mm
min.
 
24.6
(625 mm)
min.