INSTALL THE DUCTWORK 
(Ducted Hoods Only)
1. Decide where 
the ductwork 
will run 
between the 
hood and the 
outside.
2. A straight, short 
duct run will 
allow the hood 
to perform most 
efficiently.
3.  Long duct 
runs, elbows 
and transitions 
will reduce the 
performance of 
the hood. Use as few of them as possible. Larger ducting 
may be required for best performance with longer duct runs.
4.  Install wall cap or roof cap. Connect round metal ductwork 
to cap and work back towards the hood location. Use duct 
tape to seal the joints between ductwork sections.
MEASURE THE INSTALLATION
The minimum hood distance above cooktop MUST NOT BE 
LESS than 30”. 
A maximum of 36” above cooktop is highly recommended for 
best capture of cooking impurities.
 
Distances over 36” are at the installer and users discretion; 
providing that the ceiling height permits. 
PREPARE THE HOOD
6”
ROUND
 
DUCT
ROOF
 
CAP
ROUND
ELBOW
30” 
TO
 36” 
ABOVE
COOKING
 
SURFACE
WALL
 
CAP
HOOD
DECORATIVE
FLUE
HOOD
12 
1
/
2
” 
TO
 
CENTER
OF
 
BRACKET
 
HOLES
ROUND
 
ELBOW
HOOD
 
MOUNTING
BRACKET
30” 
TO
 36” 
ABOVE
COOKING
 
SURFACE
 *
3¼”
DECORATIVE
 
FLUE
 
 
6” 
ROUND
 
DUCT
ROOF
 
CAP
 
WALL
 
CAP
Unpack hood and check contents. You should receive:
1 - Hood
1 - Glass Canopy (Models B5630SS & B5636SS)
1 - Metal Canopy (Models B5730SS & B5736SS)
1 - Decorative Flue Assembly
1 - Damper / Duct Connector
1 - Lower Flue Mounting Bracket
1 - Upper Flue Mounting Bracket
1 - Hood Mounting Bracket
2 - Aluminum Grease Filters (installed in hood)
1 - Parts Bag containing:
8 - Mounting Screws (#8 x 3/8” Pan Head)
7 - Mounting Screws (#8 x 1-1/2” Flat Head)
4 - Mounting Screws (M4 x 1.0 Flat Head)
7 - Drywall Anchors
2 - Washers
4 - Decorative Washers
1 - Installation Manual
7 MOUNTING
SCREWS
(#8 X 1-1/2”
Flat Head)
7 DRYWALL
ANCHORS
8 MOUNTING
SCREWS 
(#8 x 3/8”
Pan Head)
DECORATIVE FLUE
2  WASHERS
UPPER
FLUE MOUNTING
BRACKET
HOOD
MOUNTING
BRACKET
LOWER
FLUE MOUNTING
BRACKET
DAMPER / DUCT
CONNECTOR
4 MOUNTING
SCREWS
(M4 X 1.0”
Flat Head)
4 DECORATIVE
WASHERS