Maytag MGD3100DW Datenbogen

Seite von 20
7
FIGURE 19A
 
 
  
(2) SCREWS
IGNITOR
BURNER 
TUBE
 
PRESSURE 
TAP PLUG
 
GAS VALVE 
ASSEMBLY
Determine Gas Valve Style
CHANGING THE ORIFICE (BOTH STYLES)
23.  Remove the two (2) screws securing the burner tube to 
the burner base. See Figure 19A.
FIGURE 20
 
 
 
IGNITOR
BURNER 
TUBE
GAS VALVE 
ASSEMBLY
24.  Slide burner tube forward far enough to gain access to 
orifice. Do not bump ignitor. See Figure 20.
NOTE: The ignitor is fragile.
FIGURE 19B
 
 
   
(2) SCREWS
IGNITOR
BURNER 
TUBE
 
PRESSURE 
TAP PLUG
 
GAS VALVE 
ASSEMBLY
NOTE: IF YOUR GAS DRYER HAS STYLE “A” FOLLOW STEP 
28. FOR STYLE “B” SKIP TO STEP 29 TO 32.
27.  Before proceeding, you must first determine which gas valve 
style is on the dryer. Refer to Figure 22 - Style “A” and “B”. 
FIGURE 22
STYLE “A”
 
 
 
 
TWO 
SEPARATE 
COILS
STYLE “B”
 
CAP - PERMANENTLY 
FIXED TO VALVE
 
COVER DIAL
 
ONE PIECE 
COIL
REGULATOR 
VENT CAP
25.  Remove the burner orifice from the gas valve assembly 
and replace it with the proper orifice furnished in this kit. 
Orifice number is stamped on one edge of the hex head 
of orifice. Securely tighten. See Figure 21.
Use Orifice No. 55 for Propane gas.
Use Orifice No. .049 for Butane gas.
FIGURE 21
 
 
ORIFICE
GAS VALVE 
ASSEMBLY
26.  Slide the burner tube back in place and using the screws 
removed in step 22 reattach burner tube to the burner 
assembly.  Securely  tighten  the  two  (2)  mounting  screws.                     
See Figure 19A or 19B