Dacor DR30EFS Designanleitung

Seite von 4
All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
DR30ES, DR30EFS, DR30EIS, DR30EIFS
Distinctive
 
30” Wide 
Electric Ranges
Document # PG05-008
Revised 11/09/12   Page 3/4
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
* To create a “built-in look” on the front of the cabinet, this dimension may be changed to 29 1/4” (74.3 cm), with the width at the 
notches remaining 30 1/16”. This configuration is only for models DR30EIS and DR30EIFS with side panels behind door removed.
Countertop height:  34 3/4” (88.3 cm) min.
 
 
36 7/8” (93.7 cm) max.
Countertop thickness: 1 5/8” (4.1 cm) max.
tOP vIEW - SLIDE-IN, SELF-RImmING INStALLAtION, 3” 
SIDE PANELS REmOvED
tOP vIEW - SLIDE-IN, SELF-RImmING INStALLAtION, 3” 
SIDE PANELS INStALLED
Self-rimming installation Cutout Options (Models Dr30EiS and Dr30EiFS Only)
Electrical Specifications
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30 1/16” (76.2 cm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets 
3/8” min. (9.5 mm)
 countertop overhang
10” min. (25.4 cm)
to any combustibles 
above counter both sides
19 7/8”
 (50.5 cm)
to
22 7/8”
 (58.1 cm)
19 7/8”
 (50.5 cm)
24 1/2”
 (62.2 cm)
max.
Countertop front
Rear wall or
countertop edge
countertop opening
29 1/4” (74.3 cm)
30 1/16” (76.2 cm)*
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets 
3/8” min. (9.5 mm)
 countertop overhang
10” min. (25.4 cm)
to any combustibles 
above counter both sides
22 7/8”
 (58.1 cm)
24 1/2”
 (62.2 cm)
max.
Countertop front
10
”(
25
.4
cm)
10
”(
25
.4
cm)
12” (30.5 cm)
2 1/2”
(6.4 cm)
3 1/2”
(8.9 cm)
1” (2.5 cm)
UtILIty CLEARANCE bEhIND RANGE
NEmA 14-50P PLUG
NEmA 14-50R RECEPtACLE
ELECTriCaL rEQUirEMEnTS
Electrical Circuit 
required
Total Connected 
Load**
 240 Vac 60 Hz, 4 wire*,  
50 Amp.
11.94kW (49.75 Amp.)
*Two 120 Vac hot (L1 and L2), one neutral (N1) and one ground.
**This information above is for reference only. If the above data 
does not agree with the product data label, use the data on the 
product data label.
iMPOrTanT: Models DR30ES-C and DR30EFS-C are 
freestanding ranges that come with a factory installed 4-wire 
appliance cord and NEMA 14-50P plug. This wiring configuration 
is required for freestanding ranges installed in Canada, although 
they may be used elsewhere, if local codes permit. The plug 
is designed to plug directly into a NEMA 14-50R electrical 
receptacle installed by a licensed electrician according to the 
above specifications.
Factory wiring
Model
Factory Electrical Connection
DR30ES
Power cord not installed. Not for installation in Canada.
DR30ES-C
Cord connected, for installation in Canada and U.S.A., 
where local codes permit.
DR30EFS
No power cord. Not for installation in Canada.
DR30EFS-C
Cord connected, for installation in Canada and U.S.A., 
where local codes permit.
DR30EIS
No power cord. May be installed in Canada and U.S.A.
DR30EIFS
No power cord. May be installed in Canada and U.S.A.