Thermador PRG366JG Installationsanweisungen

Seite von 90
English 25
Step 10: Burner Test and Adjustment
Install any loose components, such as burner caps and 
grates that may have been removed earlier. Be certain that 
burner caps seat properly into the burner bases. Before 
testing operation of the appliance, verify that the unit and 
the gas supply have been carefully checked for leaks and 
that the unit has been connected to the electrical power 
supply. Turn the gas shut-off valve to the open position. 
NOTICE:
All oven knobs and selectors must be set to OFF before 
powering up the range. To prevent unintended operation at 
power up, please set all oven knobs to OFF. To ensure 
customer safety in the event of power failure, the unit will 
display an error message upon reinstatement of power 
unless all oven knobs are set to OFF. Set all oven knobs to 
OFF and reset the breaker to clear the message.
Test Rangetop Burners 
Test Burner Ignition. Select a rangetop burner knob. Push 
in and turn counterclockwise to HI. The ignitor/spark 
module will produce a clicking sound. Once the air has 
been purged from the supply lines, the burner should light 
within four seconds. 
Test Flame: High Setting. Turn burner on to HI. See 
Figure 28 for appropriate flame characteristics. 
If any of the rangetop burners continue to burn mostly or 
completely yellow, verify that the burner cap is positioned 
properly on the burner base, then retest. If flame 
characteristics do not improve, call THERMADOR
®
Test Flame: Simmer Setting. Turn burner on to SIM. Verify 
that the flame travels completely around the burner. This is 
know as “carry over”. There should be a flame at each 
burner port and there should be no air gap between the 
flame and the burner. If any burners do not “carry over,” call 
THERMADOR. 
Four rangetop burners, (2) on the left side and (2) on the 
right, feature XLO
®
 setting that causes the flame to cycle 
on and off when the knob is set to the XLO range. This is 
normal operation.
Repeat these Ignition and Flame Test procedures for each 
rangetop burner. 
When Flame is Properly Adjusted:
There should be a flame at each burner port.
There should be no air gap between the flame and 
burner port. 
 F
IGURE 
28: F
LAME 
C
HARACTERISTICS
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or mostly yellow, verify
that the regulator is set for the correct fuel. After
adjustment, retest.
Some orange-colored streaking is normal during
the initial start-up.
Allow unit to operate 4-5 minutes and re-evaluate
before making adjustments.