Venting Kits
For more information, call 
1-800-901-2042, or visit us at  
www.applianceaccessories.com. In Canada, call  
1-800-807-6777 or visit us at www.whirlpoolparts.ca.
Part Number Descriptions
8171587RP
0–5" Metal vent periscope
4396037RP
0"-18" Metal vent periscope
4396011RP
18" - 29" Metal vent periscope
4396014
29" - 50" Metal vent periscope
4392892
In-Wall metal DuraVent™ Periscope
279818
4-way vent kit - white
W10186596
4-way vent kit - universal grey
4396028
Sure Connect™ venting kit  
(over-the-top installation)
4396009RP
5' Universal connect vent, flexible dryer venting
4396010RP
6' SecureConnect™ vent, flexible dryer venting
4396013RB
Dryer vent installer’s kit
4396033RP
5' flexible dryer venting with clamps
4396727RP
8' flexible dryer venting with clamps
4396004
Dryer offset elbow
4396005
Wall offset elbow
4396006RW
DuraSafe™ close elbow
4396007RW
Through-the-wall vent cap
4396008RP
4" steel dryer venting clamps - 2 pack
8212662
Flush mounting louvered vent hood 4"
Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible 
portion of the mobile home structure and must not terminate 
beneath the mobile home. Terminate the exhaust vent outside.
 
Determine vent path:
 
Select route that will provide straightest and most direct  
path outdoors.
 
Plan installation to use fewest number of elbows and turns.
 
When using elbows or making turns, allow as much room  
as possible.
 
Bend vent gradually to avoid kinking.
 
Use as few 90° turns as possible.
Vent System Chart
Number of 
90° turns  
or elbows
Type  
of vent
Box/louvered 
hoods
Angled  
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
The Vent System Chart provides venting requirements that 
will help achieve best drying performance.
Determine vent length and elbows needed for best 
drying performance:
 
Use following Vent System Chart to determine type of vent 
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified  
in Vent system chart. Exhaust systems longer than those 
specified will:
 
Shorten life of dryer.
 
Reduce performance, resulting in longer drying times  
and increased energy usage.
NOTE: Side and bottom exhaust installations have a 90º turn 
inside the dryer. To determine maximum exhaust length, add 
one 90º turn to the chart.
Install Vent System
12" min.
(305 mm)
12" min.
(305 mm)
Install exhaust hood
1.
Install exhaust hood and use caulking compound to seal 
exterior wall opening around exhaust hood.