Maytag MEDP475EW Installationsanweisungen

Seite von 20
15
Connect vent to exhaust hood
2.
Vent must fit over the exhaust hood. Secure vent to exhaust 
hood with 4" (102 mm) clamp. Run vent to dryer location 
using straightest path possible. Avoid 90° turns. Use clamps 
to seal all joints. Do not use duct tape, screws, or other 
fastening devices that extend into interior of vent to secure 
vent, because they can catch lint.
Connect Vent
Connect vent to exhaust outlet
1.
Using a 4" (102 mm) clamp, connect vent to exhaust outlet  
in dryer. If connecting to existing vent, make sure vent is 
clean. Dryer vent must fit over dryer exhaust outlet and inside 
exhaust hood. Check that vent is secured to exhaust hood 
with a 4" (102 mm) clamp.
Move dryer to final location
2.
Move dryer to final location. Avoid crushing or kinking vent. 
After dryer is in place, remove corner posts and cardboard 
from under the dryer.
Level Dryer
1.
       Not Level 
            
LEVEL                    Not Level
Check levelness of dryer from side to side. Repeat from  
front to back. 
NOTE: The dryer must be level for the moisture sensing  
system to operate correctly.
LEVEL DRYER
Tighten and adjust leveling legs
2. 
If dryer is not level, prop up using a wood block, use wrench  
to adjust legs up or down, and check again for levelness. 
Once dryer is level, make sure all four legs are snug against 