Whirlpool WEC530H0DB Installationsanweisungen

Seite von 32
11
3-wire connection: Power Supply Cord
Use this method only if local codes permit connecting chassis 
ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the strain relief on the 
cord/conduit plate on bottom of range. Allow enough slack to 
easily attach the wiring to the terminal block.
2. Use 
³⁄₈" nut driver to connect the neutral (white) wire to the 
center terminal block post with one of the 10–32 hex nuts.
3. Connect line 2 (red) and line 1 (black) wires to the outer 
terminal block posts with 10-32 hex nuts.
4. Firmly tighten hex nuts.
NOTE: For power supply cord replacement, use only a power 
cord rated at 250 volts minimum, 40- or 50-amps that is 
marked for use with nominal 1
³⁄₈" (3.5 cm) diameter 
connection opening, with ring terminals and marked for use 
with ranges.
5. Tighten strain relief screws.
IMPORTANT: Verify the tightness of the hex nuts.
6. Replace lower access cover.
4-wire connection: Power Supply Cord
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes 
Recreational vehicles
In an area where local codes prohibit grounding through the 
neutral
1. Part of metal ground strap must be cut out and removed.
2. Use a Phillips screwdriver to remove the ground-link screw 
from the back of the range. Save the ground-link screw and 
the end of the ground link under the screw.
3. Feed the power supply cord through the strain relief on the 
cord/conduit plate on bottom of range. Allow enough slack to 
easily attach the wiring to the terminal block.
4. Use a Phillips screwdriver to connect the green ground wire 
from the power supply cord to the range with the ground-link 
screw and ground-link section. The ground wire must be 
attached over the ground-link section.
A. Terminal block
B. Ground-link screw
C. UL listed strain relief
D. Power supply cord wires - large opening
A. 10–32 hex nut
B. Line 2 (red)
C. Ground-link screw
D. Neutral (white) wire
E. Line 1 (black)
A
B
D
C
A
B
C
D
E
A. Metal ground strap
B. Discard
C. Ground-link screw
A. Terminal block
B. Ground-link screw
C. UL listed strain relief
D. Power supply cord wires
A
B
C
A
B
D
C