Meyer Sound MG-3D/M Benutzerhandbuch

Seite von 32
mg-3d/m  multipurpose grid and accessories 
PN: 05.132.036.01 B2
Page 28 of 32
Meyer Sound Laboratories Inc.
www.meyersound.com
T: +1 510 486.1166
F: +1 510 486.8356
mve-milo vertical extension bars
In a MILO array, MFAL-MILO front and MRAL-MILO rear AlignaLinks at the cabinet corners couple the units for either 
flying or stacking, and allow nine positions from 0° to 5° of cabinet splay (0°, .5°, 1°, 1.5°, 2°, 2.5°, 3°, 4°, 5°). For ap-
plications where the desired splay angle is greater than the full 5° capability of the MRAL-MILO rear AlignaLinks, the 
MVE-MILO vertical extension bars can help. 
tip: 
The MVE-MILO vertical extension bars are most useful when you need to minimize high-frequency 
reflections in a specific area – such as a balcony face in a theatre or glass in an arena – in your MILO 
array’s vertical coverage. By increasing the angle between the two loudspeakers aimed at the surface you 
need to miss, you reduce the amount of sound reflected from that surface, and maximize other areas requiring 
coverage.
The two MVE-MILO extension bars replace the triangular MFAL-MILO front AlignaLinks on the upper cabinet where 
the extended angle is required. Using the MVE-MILO bars, you can extend the splay angle between loudspeakers by 
an additional 3°, 6° or 9°. This effectively provides up to 12° (3° maximum of the MRAL-MILO rear AlignaLinks plus 9° 
maximum of the MVE-MILO) splay angle. Note that on the MRAL-MILO, 4° and 5° are not used.
         
note:
 
The same quick release pins (3/8" x 1.125") used for the MFAL-MILO front AlignaLink are used 
with the MVE-MILO vertical extension bars.  MVE-MILO can be stored the same way as the MFAL-
MILO and can be used to secure a cabinet to the MCF-MILO caster frame.
         
note: 
Using too many MVE-MILO bars in a single array may create excessive splay angles, severely 
degrading array behavior and directionality. 
caution:
 when using the MVE-MILO extension bars, the total weight of the array should be always 
be calculated and be within specifications before flying an array. Do not exceed the MG-3D/M grid load 
ratings listed in Chapters 2 and 3 of this guide. 
list of contents: mve-milo vertical extension bars (40.132.130.01)
Qty
part number
description
a
2
61.132.037.02
MVE-MILO Vertical Extension Bar
a