Valve Specifications
Working Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20-120 psi (1.38 - 8.27 bar)
Standard 12 Volt Transformer Input Electrical Rating . . . . . . . . . . . . . . . . . . . . . 115V 60 Hz
Optional 12 Volt Transformer Input Electrical Rating  . . . . . . . . . . 115V 50 Hz, 230V 50 Hz, 
230V 60 Hz, 100V 60 Hz, 100V 50 Hz
Operating Ambient Temperature. . . . . . . . . . . . . . . . . . . . . 34 
° F to 120 ° F (1 ° C to 49 ° C)
Operating Water Temperature. . . . . . . . . . . . . . . . . . . . . . . 34 
° F to 100 ° F (1 ° C to 38 ° C)
13. System using 
more or less salt 
than salt control is 
set for.
a. Inaccurate setting.
b. Foreign matter in 
controller causing 
incorrect flow rates.
c. Defective controller.
a. Make correct setting.
b. Remove variable salt 
controller and flush out 
foreign matter. Manually 
position control to brine draw 
to clean controller (after so 
doing, position control to 
“purge” to remove brine from 
tank).
c. Replace defective part. 
(Contact dealer.)
14. Intermittent or 
irregular brine 
draw.
a. Low water pressure.
b. Defective injector !
a. Set pump to maintain at 
least 20 psi (1.38 bar) at 
softener.
b. Replace both injector and 
injector cap. (Contact 
dealer.)
15. No conditioned 
water after 
regeneration.
a. Unit did not regenerate.
b. No salt in brine tank.
c. Plugged injector !
d. Air check valve closed 
prematurely.
a. Check for power.
b. Add salt to brine tank.
c. Remove injector and flush it 
and injector screen.
d. Put control momentarily into 
refill to free air check. 
Replace or repair air check if 
needed. (Contact dealer.)
Problem
Possible Cause
Solution