10. Control will not 
regenerate 
automatically but 
will regenerate 
when button is 
pressed.
a. If water flow display is not 
operative, refer to Item 5.
b. Defective circuit board.
c. Incorrect hardness and 
capacity settings.
a. Same as Item 5.
b. Replace timer. (Contact 
dealer.)
c. Set to correct values. See 
Programming section.
11. Run out of soft 
water between 
regenerations.
a. Improper regeneration.
b. Incorrect salt setting.
c. Incorrect hardness or 
capacity settings.
d. Water hardness has 
increased.
e. Restricted meter turbine 
rotation due to foreign 
material in meter !
a. Repeat regeneration, 
making certain that correct 
salt dosage is used.
b. Set salt control to proper 
level. See salt setting chart. 
c. Set to correct values. See 
Programming section.
d. Set hardness to new value. 
See Programming section.
e. Remove meter housing, free 
up turbine and flush with 
clean water. Turbine should 
spin freely; if not, replace 
meter. (Contact dealer.)
12. Brine tank 
overflow.
a. Brine valve disc 1 being 
held open by foreign 
matter.
b. Uncontrolled brine refill 
flow rate.
c. Valve disc 2 not closed 
during brine draw causing 
brine refill.
d. Air leak in brine line to air 
check.
e. Improper drain control for 
injector.
f.
Drain control clogged 
with resin or other debris.
a. Manually operate valve stem 
to flush away obstruction.
b. Remove variable salt 
controller to clean it and the 
ball.
c. Flush out foreign matter 
holding disc open by 
manually operating valve 
stem.
d. Check all connections in 
brine line for leaks. Refer to 
instructions.
e. Too small of a drain control 
with a “B” or “C” injector will 
reduce draw rates. 
Reference Pressure 
Graphs.
f.
Clean drain control.
Problem
Possible Cause
Solution