6. Control 
regenerates at 
wrong time of day.
a. Power outages.
b. Clock set incorrectly.
a. Reset clock to correct time of 
day.
b. Reset clock to correct time of 
day.
7. Timer stalled in 
regeneration 
cycle.
a. Motor dead.
b. Motor runs backward.
c. No electric power at 
outlet.
d. Broken gear.
e. Defective switch.
f.
Air leak in brine 
connections.
g. Binding of camshaft.
h. Water pressure greater 
than 125 psi (8.6 bar) 
during regeneration !
i.
Defective circuit board.
a. Replace timer. (Contact 
dealer.)
b. Replace timer. (Contact 
dealer.)
c. Repair outlet or use working 
outlet.
d. Replace timer. (Contact 
dealer.)
e. Replace timer. (Contact 
dealer.)
f.
Check all junction points and 
make appropriate 
corrections.
g. Remove foreign object 
obstruction from valve discs 
or camshaft.
h. Install pressure regulator.
i.
Replace timer. (Contact 
dealer.)
8. Continuous 
regeneration. 
Camshaft does 
not stop at the end 
of regeneration.
a. Broken switch actuator 
on gear.
b. Defective switch.
a. Replace timer. (Contact 
dealer.)
b. Replace timer. (Contact 
dealer.)
9. Control will not 
regenerate 
automatically or 
when button is 
pressed.
a. Electric cord or 
transformer unplugged.
b. No electric power at 
outlet.
c. Defective motor.
d. Broken gear.
e. Binding in gear train.
f.
Defective switch.
a. Connect power.
b. Repair outlet or use working 
outlet.
c. Replace timer. (Contact 
dealer.)
d. Replace timer. (Contact 
dealer.)
e. Replace timer. (Contact 
dealer.)
f.
Replace timer. (Contact 
dealer.)
Problem
Possible Cause
Solution
1018075 Rev I.fm  Page 30  Tuesday, February 17, 2004  4:26 PM