CHAPTER  8   INTERVAL  TIMER 
8.3  Registers Controlling 12-bit Interval Timer 
 
The 12-bit interval timer is controlled by the following registers.
 
 
•  Peripheral enable register 0 (PER0) 
•  Subsystem clock supply mode control register (OSMC) 
•  Interval timer control register (ITMC) 
 
8.3.1  Peripheral enable register 0 (PER0) 
This register is used to enable or disable supplying the clock to the peripheral hardware.  Clock supply to a hardware 
macro that is not used is stopped in order to reduce the power consumption and noise. 
When the 12-bit interval timer is used, be sure to set bit 7 (RTCEN) of this register to 1. 
The PER0 register can be set by a 1-bit or 8-bit memory manipulation instruction. 
Reset signal generation clears this register to 00H. 
 
Figure 8-2.  Format of Peripheral Enable Register 0 (PER0) 
 
Address:  F00F0H     After reset:  00H     R/W 
Symbol 
<7> 6 <5> 
<4> 
<3> 
<2> 1 <0> 
PER0 RTCEN 
ADCEN 
IICA0EN 
SAU1EN
Note 
SAU0EN
0 TAU0EN
 
RTCEN 
Control of real-time clock (RTC) and 12-bit interval timer input clock supply 
 
Stops clock supply. 
•  SFR used by the real-time clock (RTC) and 12-bit interval timer cannot be written. 
•  The real-time clock (RTC) and 12-bit interval timer are in the reset status. 
 1 
Enables clock supply. 
•  SFR used by the real-time clock (RTC) and 12-bit interval timer can be read and written. 
 
Note  32, 48, and 64-pin products only. 
 
Cautions 1.  When using the 12-bit interval timer, be sure to first set the RTCEN bit to 1 and then 
set the interval timer control register (ITMC), while oscillation of the count clock is 
stable.  If RTCEN = 0, writing to the registers controlling the 12-bit interval timer is 
ignored, and, even if the register is read, only the default value is read (except the 
subsystem clock supply mode control register (OSMC)). 
<R> 
 
2.  Clock supply to peripheral functions other than the real-time clock and 12-bit interval 
timer can be stopped in STOP mode or HALT mode when the subsystem clock is 
used, by setting the RTCLPC bit of the subsystem clock supply mode control 
register (OSMC) to 1.  
 
3.  Be sure to clear the following bits to 0. 
25-pin products: bits 1, 3, 6 
32, 48, 64-pin products: bits 1, 6 
 
R01UH0305EJ0200  Rev.2.00 
 
 