Figure 12-65.  Procedure for Resuming Slave Transmission/Reception 
 
Starting setting for resumption 
Port manipulation 
Changing setting of the SPSm register
Changing setting of the SMRmn register
Changing setting of the SOm register
Port manipulation 
Writing to the SSm register
Disable data output of the target channel 
by setting a port register and a port mode 
register. 
Re-set the register to change the 
operation clock setting.
Re-set the register to change serial 
mode register mn (SMRmn) setting. 
Set the initial output level of the serial 
data (SOmn). 
Enable data output of the target channel 
by setting a port register and a port mode 
register. 
Set the SSmn bit of the target channel to 1 
(SEmn = 1: to enable operation). 
(Essential) 
(Selective) 
(Selective) 
(Selective) 
(Essential) 
(Essential) 
Clearing error flag 
(Selective) 
If the OVF flag remain set, clear this using 
serial flag clear trigger register mn 
(SIRmn). 
Starting communication 
Completing resumption setting
 
Sets transmit data to the SIOp register 
(bits 7 to 0 of the SDRmn register) and 
wait for a clock from the master. 
(Essential) 
Changing setting of the SCRmn register
Re-set the register to change serial 
communication operation setting register 
mn (SCRmn) setting. 
(Selective) 
Changing setting of the SOEm register
Set the SOEmn bit to 0 to stop output 
from the target channel. 
(Selective) 
Changing setting of the SOEm register
Set the SOEmn bit to 1 and enable 
output from the target channel. 
(Selective) 
(Essential) 
Yes 
No 
Wait until stop the communication target
(master) 
Completing master 
preparations? 
 
 
Cautions  1.  Be sure to set transmit data to the SlOp register before the clock from the master is started. 
 
2.  If PER0 is rewritten while stopping the master transmission and the clock supply is stopped, 
wait until the transmission target (master) stops or transmission finishes, and then perform 
initialization instead of restarting the transmission. 
 
Remark  m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), p: CSI number (p = 00, 01, 10, 11, 20, 21), 
mn = 00 to 03, 10, 11