Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
 
CHAPTER  12   SERIAL  ARRAY  UNIT 
R01UH0305EJ0200  Rev.2.00 
 
 
508  
Jul 04, 2013 
(2) Operation procedure 
 
Figure 12-76.  Initial Setting Procedure for UART Transmission 
 
Remark  m: Unit number (m = 0, 1), n: Channel number (n = 0, 2), q: UART number (q = 0 to 2) 
 
mn = 00, 02, 10 
 
 
<R> 
Starting initial setting 
Setting the PER0 register 
Setting the SPSm register 
Setting the SMRmn register 
Setting the SCRmn register 
Setting the SDRmn register 
Setting the SOm register 
Setting port 
Changing setting of the SOEm register 
Writing to the SSm register 
Completing initial setting 
Release the serial array unit from the 
reset status and start clock supply.
 
Set the operation clock. 
Set an operation mode, etc. 
Set a communication format. 
Set a transfer baud rate (setting the 
transfer clock by dividing the operation 
clock (f
MCK
)).
Set the initial output level of the serial 
data (SOmn). 
Enable data output of the target channel 
by setting a port register and a port mode 
register. 
Set the SOEmn bit to 1 and enable data 
output of the target channel. 
Set the SSmn bit of the target channel to 1 
and set the SEmn bit to 1 (to enable 
operation).
Initial setting is completed. 
Set transmit data to the SDRmn[7:0] bits 
(TXDq register) (8 bits) or the SDRmn[8:0] 
bits (9 bits) and start communication.
Changing setting of the SOLm register 
Set an output data level.