Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
CHAPTER  25   FLASH  MEMORY 
25.5  Processing Time for Each Command When PG-FP5 Is in Use (Reference Value) 
<R> 
 
The following shows the processing time for each command (reference value) when PG-FP5 is used as a dedicated 
flash memory programmer. 
 
Table 25-10.  Processing Time for Each Command When PG-FP5 Is in Use (Reference Value) 
Code Flash 
PG-FP5 Command 
16 KB 
32 KB 
48 KB 
64 KB 
Erasing 
1 s 
1 s 
1 s 
1.5 s 
Writing 
1.5 s 
1.5 s 
2 s 
2.5 s 
Verification 
1.5 s 
1.5 s 
2 s 
2 s 
Writing after erasing 
1.5 s 
2 s 
2.5 s 
3 s 
 
Remark  The command processing times (reference values) shown in the table are typical values under the following 
conditions. 
 
Port: TOOL0 (single-line UART) 
 
Speed: 1,000,000 bps 
 
Mode: Full speed mode (flash operation mode: HS (high speed main) mode) 
 
R01UH0305EJ0200  Rev.2.00 
 
 
814  