Renesas rl78 User Manual
RL78/G1A
CHAPTER 25 FLASH MEMORY
25.5 Processing Time for Each Command When PG-FP5 Is in Use (Reference Value)
<R>
The following shows the processing time for each command (reference value) when PG-FP5 is used as a dedicated
flash memory programmer.
Table 25-10. Processing Time for Each Command When PG-FP5 Is in Use (Reference Value)
Code Flash
PG-FP5 Command
16 KB
32 KB
48 KB
64 KB
Erasing
1 s
1 s
1 s
1.5 s
Writing
1.5 s
1.5 s
2 s
2.5 s
Verification
1.5 s
1.5 s
2 s
2 s
Writing after erasing
1.5 s
2 s
2.5 s
3 s
Remark The command processing times (reference values) shown in the table are typical values under the following
conditions.
Port: TOOL0 (single-line UART)
Speed: 1,000,000 bps
Mode: Full speed mode (flash operation mode: HS (high speed main) mode)
R01UH0305EJ0200 Rev.2.00
814